0

Honeywell HCU-2000

Contact

PAVA Controller | Perfect for Single Buildings

The HCU-2000 controller is the core device of Honeywell’s Intevio PAVA system. It easily performs many important functions such as audio storage and playback, signal processing, zone control, routing, scheduled broadcasting, monitoring and fault detection. It meets international and safety standards.

With a built-in 500W Class-D amplifier, this single controller can function as an integrated 8-zone PAVA system for better stability, cost savings and a great user experience.

FEATURES

– Mains voltage: AC 220-240 V, 50 / 60 Hz

– Rated power: 750 W

– Backup power voltage: AC 220-240 V, 50 / 60 Hz

– Mains fuse: T10AH 250 V

– Mic/Line frequency response: 85 Hz-18 KHz

– Net weight: 14.3Kg

Description

Specifications:

Model No. HCU-2000

Main Power Supply Voltage AC 220-240V, 50/60Hz

Rated Power 750W

Gross Weight 17.4Kg

Backup power supply AC 220-240V, 50/60Hz

Main Power Supply Fuse T10AH 250V

Microphone Input Sensitivity -65±3dBV

Microphone Input Impedance 250Ω

Microphone Input Frequency Response 90 Hz -13KHz

Microphone Input SNR >50dB (with A-Weight)

Auxiliary input Input channels 2

Auxiliary Input Sensitivity 1V (0dBV)

Auxiliary input Input impedance 10 KΩ

Auxiliary input Frequency response 85Hz-18KHz

Auxiliary Input SNR >77dB (with A-Weight)

Mic/Line Input Sensitivity -50dBV/0dBV, selectable

Mic/Line Input Impedance 10 KΩ

Mic/Line Input Frequency Response 85Hz-18KHz

Mic/Line Input SNR >77dB (with A-Weight)

Mic/Line Input Phantom Power DC 24V, switchable

Call Station Interface Input Signal 2V

Call Station Interface Input Impedance 20 KΩ

Call Station Interface Output Signal 2V

Call Station Interface Output Impedance 20 KΩ

Call Station Interface Frequency Response 85Hz-18KHz

Audio Output Channels Channel 1, channel 2 and recording output

Audio Output signal 1V (0dBV)

Audio Output THD <0.5%

Amplifier Control Interfaces Channels 3 (channel 1, channel 2 and backup amplifier)

Amplifier Control Interfaces Output Signal 1.4V

Amplifier Control Interfaces THD <0.5%

Amplifier Control Interfaces Control Signal Self-test signal, amplifier fault signal and power saving control signal

Loudspeaker Circuits Output Channels 8 (with group A and group B)

Loudspeaker Circuits Load 500W

Contact Inputs 10 (monitored)

Contact Outputs 8 (NO, NC & COM), “fault output, emergency output

MAX. Working Voltage for Outputs AC 250V/DC 30V

MAX. Working current for Outputs 2.5A

DC power output 24V/1A

Ethernet Port 10M/100M

Memory Capacity 1GB

Humidity < 95%, without condensation

Operating Temperature -10°C~+50°C (14°F~+122°F)

Storage Temperature -40°C~+70°C (-40°F~+158°F)

Product dimensions (W×H×D) 482 mm×133.5 mm×420 mm

Package dimension (W×H×D) 580 mm×279 mm×552 mm

Net Weight 14.3Kg

abc 24V/1A

Monitoring Loudspeaker 2W/8Ω