Honeywell PRO4200 Controllers
Contact
Professional Series Access Modules
The PRO4200 professional series family of access control modules is designed for high density installations.
Description
Specifications:
| MODULE SPECIFICATIONS | PRO4200 SERIES SINGLE READER MODULE (PRO42R1) | PRO4200 SERIES DUAL READER MODULE (PRO42R2) |
| PORT | Reader port 12/24VDC @ 500mA, OSDP; Wiegand; Dt/Clk* | 2 Reader port 12/24VDC @ 300mA, OSDP; Wiegand; Dt/Clk* |
| KEYPAD | Keypad multiplexed with card data | |
| WIRE SUPPORT | Two-wire or one-wire bi-color LED support | |
| BUZZER SUPPORT | Buzzer support only with one-wire LED control | |
| ALARM INPUTS | 2 supervised, general purpose alarm inputs with programmable circuit type | 8 supervised, general purpose alarm inputs with programmable circuit type (only 6 supervised inputs available when using PRO22ENC1, PRO22ENC2 and PRO 22ENC5 enclosures) |
| OUTPUT RELAYS (DOOR STRIKE(S) | 1 output relay, form C, 5A 40 VDC | 2 output relay, form C, 2A 30 VDC |
| OUTPUT RELAYS | 1 general purpose output relay, form C, 5A 30 VDC | 2 general purpose output relay, form C, 5A 30 VDC |
| MOUNTING | Designed to be tile-mounted using the PRO22ENC4 enclosure | N/A |
| ALARM INPUT PROPERTIES | ||
| INPUTS | Inputs may be assigned to door related functions or general purpose I/O | |
| CIRCUIT TYPE | Circuit type – normally open, normally closed, non-supervised, supervised (with standard 1K or custom end-of-line resistance 200-10K) | |
| LINE CONDITIONING | Line conditioning – programmable sensitive hold time | |
| OUTPUT CONTROL PROPERTIES | ||
| OUTPUTS | Outputs may be assigned to door related functions or general purpose I/O | |
| RELAY RATING | The relay(s) are rated to handle the inductive loads of door locking devices S-4 SUPPRESSOR CABLE TO THE DOOR OPENER | |
| CONFIGURABLE | Configurable as standard (energize to activate) or fail-safe (de-energize to activate) | |
| PULSE TIME | 1-42,400 seconds, 1-255 for door relays | |
| RS485 PORT | RS485 port, 4,000 ft (1,250m) total bus length | |
| STANDARD SPEED | 38.4 Kbps | |
| MODULE SPECIFICATIONS | PRO4200 SERIES SIXTEEN RELAY OUTPUT MODULE (PRO42OUT) | PRO4200 SERIES SIXTEEN ALARM INPUT MODULE (PRO42IN) |
| ALARM INPUTS | 2 dedicated (unsupervised) alarm inputs for tamper detection and power loss (tile-mounted only) | |
| ALARM INPUTS | N/A | 16 general purpose inputs with programmable circuit type |
| OUTPUT RELAYS | 12 general purpose output relays, form C, 5A 30 VDC (16 are available when using PRO22ENC3 tile-mounted enclosure) |
2 general purpose, form C, 5A 30 VDC relays (only one available when using PRO22ENC1, PRO22ENC2 and PRO22ENC5) |
| OUTPUT CONTROL PROPERTIES | ||
| OUTPUT | All 16-relay outputs in the tile-mount configuration (1 rack mount) are available for general purpose I/O |
Both relay outputs are available for general purpose I/O |
| DRY CIRCUIT LOGIC | The 5A relays are rated to handle dry circuit logic (Resistive) | Both relay outputs are rated to handle dry circuit logic (Resistive) |
| PULSE TIME | 1-32,400 seconds | |
| CONFIGURABLE | Configurable as standard (energize to activate) or fail-safe (de-energize to activate) |
N/A |
| ALARM INPUT PROPERTIES | ||
| INPUTS | 2 dedicated for tamper detection and power loss | All 16 inputs may be assigned to door related functions or general purpose I/O 2 dedicated for tamper and power loss |
| CIRCUIT TYPE | N/A | Circuit type – normally open, normally closed, non-supervised, supervised (with correct EOL) |
| LINE CONDITIONING | N/A | Line conditioning – programmable sensitivity and hold time |
| COMMUNICATION FEATURES | ||
| MEASUREMENTS | RS485 port, 4,000 ft (1,250m) total bus length per port | |
| SPEED | 38.4 Kbps | |