Armatura AHDU Series IP-Based Biometric Door Unit
Contact
IP-Based Biometric Door Control Central Controller.
- Superior Authentication Performance
- Advanced Door Control Functionality
- Monitored & Programmable Inputs
- PoE & 3rd Party Integration
- Threat Level & Failover Port
Description
Specifications:
AHDU-1460 General Information
Power Supply 802.3at/af PoE / 9 – 24 VDC ± 20%, 550 mA max (excluding reader current)
Master Host Interface
Ethernet: 100Base-TX
256bit AES* symmetric encryption for Controller-to-Server and Controller-to-Controller communication
Slave Host Interface BLE 5.2
Third Host Interface
Wi-Fi IEEE 802.11ac 5GHz, or 2.4GHz/5GHz IEEE 802.11n
256bit AES* symmetric encryption for Controller-to-Server and Controller-to-Controller communication
Ethernet Network Connection
Port 1:Ethernet: 100Base-TX
Port 2: Ethernet: 100Base-TX
(Configurable for Failover Port)
RS-485 Connection
Port 1: Armatura RS-485 / OSDP V2.2
Port 2: Armatura RS-485 / OSDP V2.2
Port 3: Armatura RS-485 / OSDP V2.2
(Configurable for redundant ports 2 & 3)
Number of Ports
2*TCP/IP
3*RS-485
4*Wiegand
Input Port
Monitor 4 states, resistance value (5% tolerance),
Normally open contact: use 1.2k, 2.2k. 4.7k or 10k/
Normally closed contact: use 1.2k, 2.2k. 4.7k or 10k/
Tamper IO Input* Dedicated Control Panel
Dedicated IC Control Fire Alarm IO Input & REX Input for Disaster Situation
Outputs
4 relays,
4* Form-C with dry contacts
Normally Open Contact Rating 5A @ 30Vdc
Normally Closed Contact Rating 5A @ 30Vdc
On-Board Display
Size: 2.4″, Resolution: 320*240, TFT Display
Quickly view the status of the panel, connected doors and display configuration information
On-Board Webserver
Web server for system management and configuration
Control panel for monitoring controller status,
Monitoring & Configuration Device Connection Status, Performance Status,
Server master controller settings, Network status settings and monitoring,
IP access filter, Settings SSL/TLS certificate,
Access log export, Controller reset, Debug status monitoring,
Operational log monitoring, User management,
Date & time setting, Daylight Saving time setting
NTP server setting, General status, Controller information
RFID Card Capacity 400,000 (1:N) / 800,000 (1:1)
Maximum RFID Card Number Length Supports card number length up to 512 bits
Mobile Authentication Capacity
400,000 (1:N) (Bluetooth)
400,000 (1:N) (NFC)
400,000 (1:N) (Dynamic QR Code)
Fingerprint Capacity 50,000 (1:N) / 100,000 (1:1)
Face Capacity 5,000 (1:N) / 100,000 (1:1)
Palm Capacity 3,000 (1:N) / 5,000 (1:1)
Transaction Buffer 300,000 Events
Access Levels 100,000 Levels
On-Board Access Control Points 4 on-board access points
On-Board Reader Support
3 (OSDP over RS-485)
or
4 (Wiegand) with on-board IO
Maximum Access Points 4
Maximum Readers 8
Maximum Inputs 384 (using Armatura AHEB-1602)
Maximum Outputs 385 (using Armatura AHEB-0216)
Maximum IO Board 24pcs (3 * High-speed RS-485 interfaces)
Multi-Biometric Reader Interface / RFID
Input Voltage 12 -24 Vdc +/- 10% adjustable, up to 500 mA per reader
Maximum Input Current 12 -24 Vdc +/- 10% adjustable, up to 500 mA per reader
Protocol RS-485 AES-128, OSDP Secure Channel
OSDP Mode
9600-115200 bps, OSDP V2.2, asynchronous, half duplex, 1 start bit, 8 data bits, and 1 stop bit.
3rd Party Reader: OSDP V2.2 or later supported
Wiegand Read: supports up to 128 bit / Write: Supports 26/34/37 bit and other custom tag formats
Tamper Input (Wiegand) TTL level, high > 3 V, low < 0.5 V, 5 mA source/sink max
Buzzer Output (Wiegand) TTL level, high > 3 V, low < 0.5 V, 5 mA source/sink max
LED Output (Wiegand) TTL level, high > 3 V, low < 0.5 V, 5 mA source/sink max
Input Data
Supports RS-485, OSDP, and Wiegand standards.
Maximum RS-485/OSDP cable length: 3937ft. (1200m)
Maximum Wiegand Cable Length: 328ft (100m)
IO Expansion Board Interface
Protocol RS-485 AES-128 Secure Channel, OSDP V2
OSDP Mode
9600-115200 bps, OSDP V2.2, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit.
Maximum Cable Length: 2,000 ft. (609.6m)
Input Data
OSDP and Wiegand standards supported.
Maximum Cable Length: 500 ft. (152m)
Cable Requirements
Power & Relays One twisted pair, 18 to 16 AWG
Ethernet Redundant Switch Port CAT-5, 330 ft. minimum. (100m)
Ethernet CAT-5, 330 ft. (100m) minimum
RS-485 Reader Port
9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit.
One twisted pair with conductor and shield, 120 ohm resistor, 22-18 AWG,
Maximum cable length: 3937ft (1200m)
RS-485 I/O Device Port
9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit.
One twisted pair with conductor and shield, 120 ohm resistor, 22-18 AWG
Maximum cable length: 3937ft (1200m)
Redundant Switch Port RS-485
9600-115200 bps, asynchronous, half duplex, 1 start bit, 8 data bits, and 1 stop bit.
One twisted pair with conductor and shield, 120 ohm resistor, 22-18 AWG,
Max cable length: 3937ft (1200m)
Wiegand Port 20 AWG shielded Wiegand wire, 328ft. (100m)
Mechanical
Dimensions 4.8” W x 10.2” L x 2.5” H (122 x 260 x 62.5mm)
Weight 30oz (830g)
DIN Rail Mounting
DIN35 rail supported
Compatible with UTA89 Din Rail Adapter for screwing into circuit breakers (Sold separately)
Wall Mounting
Body Material ABS-PC UL-94 V2
Environment
Temperature -22°F ~ 158°F (-30°C~70°C), Operation & Storage
Humidity 0-95% RHNC
Security Rating Securely stores data in EAL 5+ certified electronic chips
Software Interface
TCP/IP Mode Ethernet: 100Base-TX
TCP/IP Protocol NTP, SNMP V2 /V3, 802.1X, VLAN, SSH, MQTT, IPv4, IPv6, DNS, DDNS
TCP/IP Encryption TLS1.2 compliant, AES-256 end-to-end secure communication channel
TCP/IP Communication Spada Protocol over MQTT
Supported Software Armatura One Security System