Honeywell PRO4200 Controllers

Liên hệ

Professional Series Access Modules

The PRO4200 professional series family of access control modules is designed for high density installations.

Description

Thông số kỹ thuật:

MODULE SPECIFICATIONS PRO4200 SERIES SINGLE READER MODULE (PRO42R1) PRO4200 SERIES DUAL READER MODULE (PRO42R2)
PORT Reader port 12/24VDC @ 500mA, OSDP; Wiegand; Dt/Clk* 2 Reader port 12/24VDC @ 300mA, OSDP; Wiegand; Dt/Clk*
KEYPAD Keypad multiplexed with card data
WIRE SUPPORT Two-wire or one-wire bi-color LED support
BUZZER SUPPORT Buzzer support only with one-wire LED control
ALARM INPUTS 2 supervised, general purpose alarm inputs with programmable circuit type 8 supervised, general purpose alarm inputs with programmable circuit type (only 6 supervised inputs available when using PRO22ENC1, PRO22ENC2 and PRO 22ENC5 enclosures)
OUTPUT RELAYS (DOOR STRIKE(S) 1 output relay, form C, 5A 40 VDC 2 output relay, form C, 2A 30 VDC
OUTPUT RELAYS 1 general purpose output relay, form C, 5A 30 VDC 2 general purpose output relay, form C, 5A 30 VDC
MOUNTING Designed to be tile-mounted using the PRO22ENC4 enclosure N/A
ALARM INPUT PROPERTIES
INPUTS Inputs may be assigned to door related functions or general purpose I/O
CIRCUIT TYPE Circuit type – normally open, normally closed, non-supervised, supervised (with standard 1K or custom end-of-line resistance 200-10K)
LINE CONDITIONING Line conditioning – programmable sensitive hold time
OUTPUT CONTROL PROPERTIES
OUTPUTS Outputs may be assigned to door related functions or general purpose I/O
RELAY RATING The relay(s) are rated to handle the inductive loads of door locking devices S-4 SUPPRESSOR CABLE TO THE DOOR OPENER
CONFIGURABLE Configurable as standard (energize to activate) or fail-safe (de-energize to activate)
PULSE TIME 1-42,400 seconds, 1-255 for door relays
RS485 PORT RS485 port, 4,000 ft (1,250m) total bus length
STANDARD SPEED 38.4 Kbps

 

MODULE SPECIFICATIONS PRO4200 SERIES SIXTEEN RELAY OUTPUT MODULE (PRO42OUT) PRO4200 SERIES SIXTEEN ALARM INPUT MODULE (PRO42IN)
ALARM INPUTS 2 dedicated (unsupervised) alarm inputs for tamper detection and power loss (tile-mounted only)
ALARM INPUTS N/A 16 general purpose inputs with programmable circuit type
OUTPUT RELAYS 12 general purpose output relays, form C, 5A 30 VDC
(16 are available when using PRO22ENC3
tile-mounted enclosure)
2 general purpose, form C, 5A 30 VDC relays
(only one available when using PRO22ENC1, PRO22ENC2
and PRO22ENC5)
OUTPUT CONTROL PROPERTIES
OUTPUT All 16-relay outputs in the tile-mount configuration
(1 rack mount) are available for general purpose I/O
Both relay outputs are available for general purpose I/O
DRY CIRCUIT LOGIC  The 5A relays are rated to handle dry circuit logic (Resistive) Both relay outputs are rated to handle dry circuit logic (Resistive)
PULSE TIME 1-32,400 seconds
CONFIGURABLE Configurable as standard (energize to activate) or
fail-safe (de-energize to activate)
 N/A
ALARM INPUT PROPERTIES
INPUTS 2 dedicated for tamper detection and power loss All 16 inputs may be assigned to door related functions or general purpose I/O 2 dedicated for tamper and power loss
CIRCUIT TYPE N/A Circuit type – normally open, normally closed,
non-supervised, supervised (with correct EOL)
LINE CONDITIONING N/A Line conditioning – programmable sensitivity and hold time
COMMUNICATION FEATURES
MEASUREMENTS RS485 port, 4,000 ft (1,250m) total bus length per port
SPEED 38.4 Kbps