{"id":15601,"date":"2025-01-17T09:08:24","date_gmt":"2025-01-17T02:08:24","guid":{"rendered":"https:\/\/www.tid.vn\/?post_type=product&#038;p=15601"},"modified":"2026-01-13T10:37:40","modified_gmt":"2026-01-13T03:37:40","slug":"honeywell-mpa2-access-control-panel","status":"publish","type":"product","link":"https:\/\/www.tid.vn\/en\/san-pham\/honeywell-mpa2-access-control-panel","title":{"rendered":"Honeywell MPA2 Access Control Panel"},"content":{"rendered":"<p><strong>Specifications:<\/strong><\/p>\n<p><strong>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt:\u00a0<\/strong><\/p>\n<table style=\"height: 1611px;\" width=\"1016\">\n<tbody>\n<tr style=\"height: 42.4444px;\">\n<td style=\"text-align: center; height: 42.4444px; width: 1006.89px;\" colspan=\"3\"><strong><span style=\"color: #ff0000;\">MPA2 READER\/DOOR CONFIGURATIONS<\/span><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 145.528px;\"><\/td>\n<td style=\"text-align: center; height: 24px; width: 268.875px;\"><strong>SPECIFICATIONS\u00a0<\/strong><\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\"><strong>\u00a0MPA2<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 168px; width: 145.528px;\" rowspan=\"3\"><strong>Communications<\/strong><\/td>\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Built-in Communication Options<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">Ethernet; RS-485; USB<\/td>\n<\/tr>\n<tr style=\"height: 72px;\">\n<td style=\"text-align: center; height: 72px; width: 268.875px;\">\u00a0I\/O Expansion Module<br \/>\nConnectivity<\/td>\n<td style=\"text-align: center; height: 72px; width: 581.375px;\">Use RS-485 Port to connect a maximum of 2 downstream I\/O modules (NX4)(4)<br \/>\n(Output or Input)<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">\u00a0Controller Loop Capability<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">EVL: 16 MPA2 or NetAXS123 RS-485: 9 MPA2 and\/or NetAXS123 panels total (8+1)(1,2)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 72px; width: 145.528px;\" rowspan=\"3\"><strong>Readers\/Doors<\/strong><\/td>\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">\u00a0Door\/Reader Capability<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">2 Door\/4 Readers &#8211; 4 Door\/8 Readers(3)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">\u00a0Expandability<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">Expandable to 36 Doors\/72 Readers per controller loop(1,2)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Reader Compatibility<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">OSDP:V2 and Standard Wiegand Protocol supported<\/td>\n<\/tr>\n<tr style=\"height: 120px;\">\n<td style=\"text-align: center; height: 240px; width: 145.528px;\" rowspan=\"3\"><strong>Outputs<\/strong><\/td>\n<td style=\"text-align: center; height: 120px; width: 268.875px;\">Number of Outputs<\/td>\n<td style=\"text-align: center; height: 120px; width: 581.375px;\">\u00a04 SPDT (jumper-selectable NO or NC contacts) per door rated at 3 A @ 28 VDC;<br \/>\n4 Open Collector outputs (OC) rated at 16 mA @ 12 VDC: Reader LED (Aux) and<br \/>\nReader Buzzer (Aux) per door are available<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Output Expandability<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">\u00a0Expandable to 36 total outputs using max. 2 NX4 Relay Output Boards(4)<\/td>\n<\/tr>\n<tr style=\"height: 72px;\">\n<td style=\"text-align: center; height: 72px; width: 268.875px;\">Relay Power Source<\/td>\n<td style=\"text-align: center; height: 72px; width: 581.375px;\">\u00a0Selectable: 12 VDC Self-Powered source or 0\u201328 VDC externally supplied source<br \/>\n(USA only)<\/td>\n<\/tr>\n<tr style=\"height: 72px;\">\n<td style=\"text-align: center; height: 144px; width: 145.528px;\" rowspan=\"3\"><strong>Inputs<\/strong><\/td>\n<td style=\"text-align: center; height: 72px; width: 268.875px;\">Number of Inputs<\/td>\n<td style=\"text-align: center; height: 72px; width: 581.375px;\">8 (+4) Configurable four-state supervised input points (Factory Default Settings are: Status, REX, Reader Tamper A, Reader Tamper B, Ext. Tamper, and General Input)<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Input Expandability<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">Inputs Expandable to 68 with max. 2 NX4IN Relay Input Boards(4) (USA only)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Panel Tamper (3X)<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">Panel Door, Off-Wall and External Tamper<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 120px; width: 145.528px;\" rowspan=\"3\"><strong>Power Inputs<\/strong><\/td>\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Unit Input<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">100 to 240 VAC, 50\/60 Hz Input provides 13,8 VDC, 3.5 A Output, Battery Voltage Low Shutdown at 10.50V<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Socket or Hardware AC Input (IEC)<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">MPA1002UMPS only<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Control Board Power Input<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">13,8 VDC (+\/- 10%) from included Power Supply<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 72px; width: 145.528px;\" rowspan=\"2\"><strong>\u00a0Power Outputs<\/strong><\/td>\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Power for Locks\/Strikes\/ Reader(s)\/Input Devices<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">1,25 A per door for locks\/strikes, Readers, and Input Devices (2,5A @ 12VDC Total)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Backup Battery System<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">12 VDC, 7 Ah Battery<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 72px; width: 145.528px;\" rowspan=\"2\"><strong>\u00a0Enclosure<\/strong><\/td>\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Material<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">Metal<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Wiring Access Holes\/Knockouts<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">24<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 120px; width: 145.528px;\" rowspan=\"3\">\u00a0<strong>Installation<\/strong><\/td>\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Removable Terminal Blocks with Colour-coded Labels<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">Battery\/PSU<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Graphic Wiring Info Cards\/Labels<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">Yes<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Captive Mounting Hardware<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">Yes<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 264px; width: 145.528px;\" rowspan=\"8\">\u00a0<strong>System<\/strong><br \/>\n<strong>\u00a0Information<\/strong><\/td>\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Real Time Clock<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">Global Geographic Time Zone support; Daylight Saving Time support<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Clock Synchronization<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">Yes: via NTP Network Server<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Processor<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">IMX6-X1<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">System Mean Time Between Failures<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">250,000 Hours<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Temperature Ratings<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">Operating: 0\u00b0C to 49\u00b0C (32\u00b0F to 120\u00b0F) Storage: -55\u00b0C to 85\u00b0C (-67\u00b0F to 185\u00b0F)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Humidity<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">93% Non-Condensing<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Lead Acid Batteries<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">-40\u00b0C to 50\u00b0C (-40\u00b0F to 122\u00b0F)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Certifications and Approvals<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">EMC\/CE and FCC Compliant; UL 294 Listing, ULC319<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 72px; width: 145.528px;\" rowspan=\"2\"><strong>Physical<\/strong><\/td>\n<td style=\"text-align: center; height: 24px; width: 268.875px;\">Dimensions<\/td>\n<td style=\"text-align: center; height: 24px; width: 581.375px;\">14.1 inch (360 mm) x 16.1 inch (410 mm) x 4.3 inch (110 mm)<\/td>\n<\/tr>\n<tr style=\"height: 48px;\">\n<td style=\"text-align: center; height: 48px; width: 268.875px;\">Weight<\/td>\n<td style=\"text-align: center; height: 48px; width: 581.375px;\">6.0 Kg approx. (Battery not included &#8211; Includes Control Panel and Power Supply)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p style=\"text-align: justify;\">Honeywell\u2019s new MAXPRO\u00ae Access MPA2-Door controller provides solutions for installations of any size.<\/p>\n","protected":false},"featured_media":11290,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.tid.vn\/en\/wp-json\/wp\/v2\/product\/15601"}],"collection":[{"href":"https:\/\/www.tid.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.tid.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tid.vn\/en\/wp-json\/wp\/v2\/comments?post=15601"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tid.vn\/en\/wp-json\/wp\/v2\/media\/11290"}],"wp:attachment":[{"href":"https:\/\/www.tid.vn\/en\/wp-json\/wp\/v2\/media?parent=15601"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}